Accuracy of assessments for diagnosis of vestibular neuritis
False positive rate | Specificity | Sensitivity | |
b-HIT | 0.87 (0.75, 0.95) | 0.79 (0.68, 0.87) | 0.2125 |
HINTS | 0.83 (0.70, 0.92) | 0.86 (0.77, 0.93) | 0.1375 |
HINTS+ | 0.83 (0.70, 0.92) | 0.89 (0.80, 0.95) | 0.1125 |
v-HIT | 0.89 (0.77, 0.96) | 0.94 (0.86, 0.98) | 0.0625 |
v-HINTS | 0.83 (0.70, 0.92) | 0.96 (0.89, 0.99) | 0.0375 |
v-HINTS+ | 0.83 (0.70, 0.92) | 0.96 (0.89, 0.99) | 0.0375 |
b-HIT, bedside head impulse test; HINTS+, Head Impulse, Nystagmus and Test of Skew; v-HINTS, video-HINTS; v-HIT, video-HIT.